Applications
|
Characteristics
|
These heating cables are mainly used as heat tracing tools to stabilise temperature of liquid transferring pipes and liquids in manay industrial facilities like thermal power plants, chemical plants, etc. These cables are the most important part of the heat tracing systems. They also can be used safely to prevent moisture and icing from cooling systems.
|
PRODUCT CODE :535
KS: Silicone insulated core, silicone outer sheath cuttable heating cable |
PRODUCT CODE :536
KS/C: Silicone insulated core, silicone outer sheath copper wire braided cuttable heating cable |
|
PRODUCT CODE :537
KS/S: Silicone insulated core, silicone outer sheath steel wire braided cuttable heating cable |
Technical Details
|
KS - KS/C - KS/S
|
Conductor Diameter:
|
2x0,75 mm² Tinned Copper (Optional)
|
Heating Wire:
|
Nickel Chrome or Nickel Copper
|
Outer Diameter:
|
5,00 mm x 7,00 mm / 6,00 mm x 8,00 mm / 8,00 mm x 10,00 mm
|
Max. Ohm.:
|
---
|
Max. Voltage:
|
220 - 230 V
|
Max. Power(wattage):
|
20 w/m --> 60 w/m
|
Max. Working Temperature:
|
-70°C / +200°C
|
Tolerance:
|
Resistance: ± %10
Diameter: ±0,2 mm
Length:± %1
|
Ending Insulation:
|
Shiring Tube or Silicone Ending Piece
|
Max. Circuit Length:
|
40 - 80 meter
|