Applications
|
Characteristics
|
These heating cables are mainly used to prevent ice formation in order to flow water properly from roof gutters and downspouts. By this way, it also provides an extra and general protection to building facades. By preventing from icicles, it helps to protect people and prevent from occurance of dangerous situations around buildings.
|
PRODUCT CODE :533/1
KSP/C: Silicone insulated, silicone common sheath, copper wire braided, poliolefin outer sheath constant wattage heating cable |
PRODUCT CODE :534/2
KSP/C: Silicone insulated, silicone common sheath, steel wire braided, poliolefin outer sheath constant wattage heating cable |
|
Note: These heating cable consists of paralel resistance circuits, and it has contact points at every 50 cm. It can be cut to desired length.
|
Technical Details
|
KSP/C - KSP/S
|
Conductor Diameter:
|
2x0,75 mm² Tinned Copper
|
Heating Wire:
|
Nickel Chrome or Nickel Copper
|
Outer Diameter:
|
8,00 mm x 11,00 mm
|
Max. Ohm.:
|
1613 ohm/m
|
Max. Voltage:
|
220 - 230 V
|
Max. Power(wattage):
|
30 w/m
|
Max. Working Temperature:
|
-30°C / +95°C
|
Tolerance:
|
Resistance: ± %10
Diameter: ±0,2 mm
Length:± %1
|
Ending Insulation:
|
Shiring Tube or Silicone Ending Piece
|
Max. Circuit Length:
|
80 meter
|