ENG-DHC SILICONE INSULATED DRAIN HEATING CABLES DS2

ENG-DHC SILICONE INSULATED DRAIN HEATING CABLES DS2

 
 
Applications
Characteristics
These heating cables are usually used to prevent ice formation of water inside of pipes of cold room cooling equipments. As a result, they contribute to systems to function for a long period of time efficiently.
PRODUCT CODE :531
DS2: Silicone insulated twin core drain heating cable
 
 
 
 
Technical Details
DS2
Conductor Diameter:
0,50 mm²
Heating Wire:
Nickel Chrome or Nickel Copper
Outer Diameter:
5,00 mm - 7,00 mm
Max. Ohm.:
5000 ohm/m
Max. Voltage:
220 - 230 V
Max. Power(wattage):
40 w/m - 50 w/m
Max. Working Temperature:
-60°C / +200°C
Tolerance:
Resistance: ± %10
Diameter: ±0,2 mm
Length:± %1
 
 
 
 
 
Total Length (m)
Heating Section (m)
40 W/M
50 W/M
2
1
40
50
2,5
1,5
60
75
3
2
80
100
4
3
120
150
5
4
160
200
6
5
200
250
7
6
240
300
8
7
280
350