Applications
|
Characteristics
|
These heating cables are usually used to prevent ice formation of water inside of pipes of cold room cooling equipments. As a result, they contribute to systems to function for a long period of time efficiently.
|
PRODUCT CODE :528
DST: Silicone insulated single core drain heating cable |
Technical Details
|
DST
|
Conductor Diameter:
|
0,75 mm² - 1,00 mm² - 1,50 mm² Optional
|
Heating Wire:
|
Nickel Chrome or Nickel Copper
|
Outer Diameter:
|
5,30 mm - 5,80 mm
|
Max. Ohm.:
|
5000 ohm/m
|
Max. Voltage:
|
500 V
|
Max. Power(wattage):
|
50 w/m
|
Max. Working Temperature:
|
-60°C / +200°C
|
Tolerance:
|
Resistance: ± %10
Diameter: ±0,2 mm
|